Choice of warmth should avoid errors

In recent years, more and more housing construction of softwood wall panels adopts floor heating radiation systems. In order to prevent consumers from entering the wrong zone when purchasing floors, geothermal heating floors have entered people's lives. Experts of many professional flooring organizations have answered questions frequently encountered in on-site heating floor heating. Excerpts are provided for your reference.

Misunderstanding: The thicker the floor, the more thermal insulation

The thickness of the wooden floor is a factor that determines whether the foot feels comfortable. Therefore, when Ms. Wang was purchasing floor heating, she still chose the floor with a large thickness like ordinary floor, and mistakenly thought that the warm floor was thicker and more comfortable. However, after returning home to the floor, winter was not warm at all.

Expert analysis: Cork wood is a poor conductor, and the ground heat is transmitted to the surface through the floor, and there will be heat loss. Moreover, due to the large temperature difference between the upper and lower floors, it will inevitably lead to great deformation of the floor, causing twisting and cracking of the floor, and the dimensional stability cannot be guaranteed. Therefore, in order to reduce the loss of thermal energy, floors with a thickness of 8 mm or more should be selected for floor heating. In addition, when the floor is heated, the water is quickly dissipated, and floor separation is likely to occur. Experts recommend that consumers try to use a small size floor heating to make it heated evenly.

Misunderstanding 2 All floors can be floor heating

When asked by the public Liu Xiaolu whether the floors being sold can be floor-heated, many shopping guides will certainly tell Xiao Liu: “There is absolutely no problem. We sell floor heating.” So Xiao Liu thinks that all floors can be floor-heated. .

Expert analysis: Geothermal heating is to heat the floor through a heating tube under the floor, and then evenly radiate heat to the interior to achieve heating effect. Therefore, floor heating cannot use ordinary floors but special floor heating. Dedicated floor heating must meet stringent requirements: high substrate density, good internal bond strength, and water thickness expansion rate of 2.5% or less, in order to ensure long-term no cracking, deformation, and low formaldehyde emission at high temperatures. Because the higher the temperature, the greater the amount of formaldehyde released, especially if it is used indoors in relatively closed rooms in winter, it is more likely to exceed the standard.

Mistakes No pressure test before three floor pavements

"I thought that the house was over and I could relax. I didn't think the irritating things were still in the back." When it comes to the floor of the house, Pharaoh had a grievance. After the original warm floor was finished, Pharaoh let the decoration company conduct a pressure test. However, the decoration company let the old king rest assured that the promise of quality is certainly no problem. As a result, when the heating began in the winter, the geothermal pipes had actually leaked, and there was a clear hole above it.

Expert analysis: After the geothermal paving is completed and the floor is laid, the owner is better to check the use of geothermal energy, and the pressure test is a must. If you do not pay attention, it will bring a lot of hidden trouble to your life later. As long as the water injection into the pipeline, after the pressure rise to the required test standards, keep it for more than 30 minutes, and observe whether there is water leakage. There is a gas release valve on the geothermal water separator. If you turn on the gas, you can see that there is no leak in the pipe. If you don't run out of gas and don't feel relieved, you can let the plumber do another stress test while changing the waterway.

Misunderstanding four put legless furniture on the floor

"My home has not been renovated for more than half a year. The floor of the bedroom is a bit distorted." Mr. Yang is puzzled.

Later, after finding a professional to check it out, he realized that the bedroom was the one that had caused the disaster. Mr. Yang's bed had no legs, and the entire bed was in direct contact with the ground, and the heat was stuck under the bed.

Expert analysis: If the indoor pavement is floor heating floor, do not fix the decoration or place legless furniture on the floor as much as possible. Because floor heating is a cooling surface, hot air circulates from the bottom upwards, creating a greenhouse effect. If the legless furniture is placed on the floor, the heat dissipation surface will be reduced, which will not only lead to a reduction in the thermal effect, but also will not allow the heat to be fully dissipated, so that the heat will suffice at the wooden floor, and the floor will easily be deformed.

Misunderstanding of the five floor pavement is completed without environmental acceptance

Mr. Fan prepares to get married in "11." In order to be able to enter a new house in order to get married, Mr. Fan requested the decoration company to speed up the construction process. After the floor was finished, Mr. Fan was bent on completing it in advance and thought that it was unnecessary to do an environmental test. This can be omitted.

Expert analysis: Because floor heating floors are mostly compound floors, there is a problem of formaldehyde emission itself. After heating the local warm floor, the release of formaldehyde has been exacerbated. Therefore, after paving the warm floor, we must do environmental protection acceptance to ensure that the release of free formaldehyde reaches the standard (national standard is 1.5mg/L), it will not cause harm to the owner's physical and mental health.